loading

Сосредоточьтесь на разработке технологии управления литиевыми аккумуляторными батареями, лидера отрасли с 2015 года — Huawen.

How to Revive an Over-Discharged Lithium Battery Pack | Huawen New Power

Over-discharge is a common and potentially dangerous state for lithium battery packs. This guide explains when revival is possible, safe professional procedures for gently recharging a mildly over-discharged pack, and clear red flags when revival must be avoided.

technician testing battery voltage
Safety first: measure and inspect the pack before any recovery attempt.

Over-discharge occurs when a lithium cell’s voltage falls below its safe minimum. Typical thresholds depend on chemistry, but for common lithium-ion cells the practical critical ranges are:

  • Safe / normal: > 3.0 V per cell
  • Risky / requires caution: 2.0–3.0 V per cell
  • Dangerous / do not revive: < 2.0 V per cell

Causes include long-term storage without maintenance, defective BMS, parasitic drains, or misused chargers/devices.

Condition Recommended Action
Pack > 3.0 V per cell Normal charging allowed; run capacity test afterwards.
2.0–3.0 V per cell Possible to revive with current-limited pre-charge under controlled conditions.
< 2.0 V per cell Do not attempt revival. Professional lab inspection or safe recycling required.
Visible swelling, leakage, smell, or heat Stop immediately. Treat as hazardous — isolate and contact a professional.
Warning: If you are not a trained technician or lack a properly current-limited power supply and safe test environment, do not attempt to revive over-discharged lithium batteries.

The following is a standard professional approach used by trained engineers in a controlled lab environment. It is not a DIY recipe.

  1. Visual & electrical inspection: Check for swelling, leakage, burnt smells, loose connections, and measure per-cell voltages.
  2. Isolate the pack: Work on an insulated bench with fire suppression nearby; remove external loads and the pack from devices.
  3. Use a current-limited DC power supply (CC mode):
    • Set current limit to 0.02–0.1 C (for example, 100–500 mA for a 5 Ah pack) — choose the lower end if unsure.
    • Set voltage limit to a safe pre-charge ceiling, typically 3.0–3.2 V per cell.
  4. Gently pre-charge: Connect and allow the pack voltage to rise slowly while closely monitoring temperature and current. Stop immediately if temperature rises >5–8°C above ambient or if unusual behavior appears.
  5. Switch to normal CC/CV charger: Once cell voltages recover above ~3.0 V, transfer to a proper charger and complete a full CC/CV charge cycle.
  6. Perform acceptance tests: Capacity test (C/2 or C/3), internal resistance measurement, and a couple of shallow discharge cycles to evaluate health and balance.
  7. Decide fate: If capacity >70–80% of rated and IR is within spec, the pack may be returned to service with monitoring. Otherwise, recycle or refurbish cell-level if possible.

Note: Specific voltages/current tolerances vary by cell chemistry and manufacturer. Always follow the cell maker’s datasheet and your company safety procedures.

Do not attempt recovery and arrange for professional handling or disposal if any of these are present:

  • Per-cell voltage below 2.0 V with unknown duration
  • Visible swelling / bulging or signs of gas generation
  • Signs of short circuit, water damage, or fire exposure
  • Strong chemical smell, burnt insulation, or hot surfaces
  • Pack was stored fully discharged for months without periodic top-up

If a pack is judged unsafe or beyond economical repair, do not throw it in regular trash. Follow local hazardous waste rules — isolate the pack in a non-combustible container and contact an authorized battery recycler or your supplier for guidance.

  • Use a BMS with reliable low-voltage cutoff and cell balancing.
  • Implement periodic maintenance charging for standby packs in storage.
  • Design products with sleep/hibernation modes to prevent parasitic drains.
  • Provide user instructions and warnings about leaving devices connected or unused for long periods.
  • Deploy remote monitoring for critical battery fleets (SOC/SOH telemetry).

Recovering an over-discharged lithium pack is sometimes possible, but it carries real risks. Successful revival requires proper tools, engineering knowledge, and a controlled environment. When in doubt, treat the pack as potentially hazardous and consult professional engineers or your battery supplier.

Contact Huawen New Power — Technical Support & Safe Battery Handling

предыдущий
Как безопасно проводить испытания ёмкости и напряжения | Руководство по тестированию литиевых аккумуляторов
Рекомендуется для вас
нет данных
Свяжись с нами
+86-15994805048
Дунгуань Хуавэнь Нью Пауэр Ко., Лтд.

Компания Dongguan Huawen New Power Co., Ltd. — профессиональный производитель литиевых аккумуляторов, объединяющий исследования и разработки, производство и продажи. Компания была основана в 2018 году и расположена в городе Дунгуань, провинция Гуандун.

Свяжитесь с нами
Контактный человек: Олина Чанг
WhatsApp: 0086-15992786791
Добавить:
Инновационный индустриальный парк Сунгу Юнгу Даланг, № 1. 388, дорога Янсинь, деревня Янчонг, город Даланг, город Дунгуань, ГУА, Китай
Авторские права © 2024 Дунгуань Хуавэнь Нью Пауэр Ко., Лтд. - huawennewpower.com | Карта сайта | Политика конфиденциальности
Связаться с нами
email
whatsapp
Свяжитесь с обслуживанием клиентов
Связаться с нами
email
whatsapp
Отмена
Customer service
detect